Infrared Thermometer Instruction Manual

Infrared Thermometer Instruction Manual 5,0/5 4901 votes

Quickly identify HVAC efficiency, engine exhaust problems, overheating circuits and more with the Ames™ Instruments rugged non-contact infrared thermometer. This compact IR thermometer has an easy-to-use backlit display for use in all environments. Precise laser targeting lets you pinpoint heat leaks and solve problems faster. View and Download Klein Tools IR5 instruction manual online. Dual-laser Infrared Thermometer. IR5 Thermometer pdf manual download.

Thank you for purchasing this Forehead Infrared Thermometer. Please read this instruction manual completely before using your unit to ensure safe use, accurate results and long life of the thermometer. This product is intended for household use; this product is not intended to diagnose or treat any health problem or disease. Users Manual 6 Maintenance Caution To avoid damage to the Product, do not leave the thermometer on or near objects of high temperature. How to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16. How to Clean the Product.

Infrared Thermometer Instruction Manual - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Infrared Thermometer Instruction Manual.

Advertising

Irt207, Heat seeker, Infrared thermometer. Read online or download PDF. General Tools and Instruments IRT207 User Manual. Instruction Manual Infrared Thermometer model 02084 Features & Benefits SIDE 1. Laser Sight For aiming accuracy. Backlight.Infrared Sensor 3. Trigger Pull to turn on unit and measure temperature. Battery Cover DISPLAY 5. HOLD Indicator Displays when Trigger is released and the last recorded temperature is being shown. SCAN Indicator.

1. Introduction

Congratulations on your purchase of the new IRT207
Heat Seeker

TM

InfraRed Thermometer (IRT). This IRT is

an 8:1 non-contact temperature measuring instrument
using infrared technology and laser sighting. Features
include a 4 digit backlit LCD, scan/hold function and
auto power off (7 secs). To measure a temperature,
point the unit at the object, pull the measuring trigger
and hold. Make sure the target area is larger than the
unit’s spot size.

2. Safety Information

CAUTION: Use of controls or adjustments or
performance of procedures other than those specified
herein may result in dangerous radiation exposure.

• DO NOT submerge the unit in water.

• This product is not designed for use in medical

evaluations. The product can only be used to
measure body temperature simply for reference.
The IRT is meant for industrial and commercial uses.

LASER WARNING NOTE!

Do not point laser directly at eye.
Use caution around reflective surfaces.
Keep out of reach of children.

This instrument conforms to the following standards:

EN61326: Electrical equipment for measurement, control

and laboratory use.

IEC61000-4-2: Electrostatic discharge immunity test.

IEC61000-4-3: Radiated, radio-frequency,

electromagnetic field immunity test.

Scunci

IEC61000-4-8: Power frequency magnetic field immunity

test.

Tests were conducted using a frequency range of
80-1000MHz with the instrument in three orientations.
The average error for the three orientations
is ±1.0ºF (±0.5ºC) at 3V/m throughout
the spectrum. However, between
781-1000MHz at 3V/m,
the instrument may not
meet its stated accuracy.

3. Specifications

4. Operation of Instrument
4-1 Quick Start

To measure a temperature, point the unit at the target you
want to measure, pull the trigger and hold. Move closer to
or farther from the target until it appears about the same
size as the laser’s circular measurement ‘spot’, which has
a D:S ratio (Field of View) of 8:1. The single spot of laser
is used for aiming purposes only.
The unit displays temperatures in either ºF or ºC.
Replace the battery when the battery voltage drops
below the voltage for reliable operation and the low
battery symbol

appears.

Temperature Range

-4º to 608ºF (-20º to 320ºC)

Accuracy

±2% of reading or 3.6°F (2°C),
whichever is greater

Field of View

8:1

Laser Type,

Class 2, <1mW @655nm

Output/Wavelength

Repeatability

±1ºC (±1.8ºF)

Response Time

500 ms.

Operation Temp.

32º to 104ºF (0º to 40ºC) @ 10 to 90% RH

Auto Power Off

Automatically after 7 sec.

Emissivity

Fixed at 0.95

Scunci Instruction Manual

Storage Temp.

14º to 122ºF (-10º to 50ºC)

ºF/ºC Switchable

YES

Backlight

YES

Laser Sight Switchable YES

Battery Type

“9V” battery (included)

Battery Life

16 hrs

Dimension

5.98 x 4.65 x 1.26 in. (152 x 118 x 32 mm)

Weight

4.22 oz. (120g) without battery

Accessory

“9V” battery, Instruction manual

5. Maintenance

Cleaning the lens: Blow off loose particles using clean
compressed air. Gently brush remaining debris away
with a camel’s hair brush. Carefully wipe the surface
with a moist cotton swab. The swab may be moistened
with water.

NOTE:

DO NOT use solvents to clean the glass lens.

Cleaning the housing:

Use soap and water on a damp sponge or soft cloth.

Battery Low

Temperature Display

SCAN

ºF/ºC Switch

Laser ON/OFF Indication

ºF/ºC Switch Indication

HOLD

Laser ON/OFF Switch

IRT207

Heat Seeker

TM

Infrared Thermometer

Ames Infrared Thermometer Ir 12 Manual

©2014 GENERAL TOOLS & INSTRUMENTS New York, NY 10013

Motorola gp328 manual. Montreal, Canada H9R 1E1

Laser Certification Label
(on side of unit)

Advertising

Infrared Thermometer Instruction Manual Download

Popular Brands

Infrared Thermometer User Manual

Popular manuals